Eaton 9SX 6000i RT3U 6000VA/5400W
Šifra proizvoda
C_9SX6KIRTBrand
EATONModel
-Tip
-PartNo
-EAN
743172039354Jamstvo
24Dostupnost
Neraspoloživo
2.959,00 Eur
Povrat robe moguć unutar 14 dana isključivo za fizičke osobe po odredbama na našim stranicama
General Topology On-line double conversion with PFC (Power Factor Correction) system Configuration Rack/Tower Part Number 9SX6KiRT Rating (VA/Watts) 6000/5400 Dimensions (H x W x D, mm) 440 x 130 x 685 Weight (kg) 48 Warranty 2 years warranty Rail Kit Included Yes Electrical Input Connection Hardwired - see manual for terminal block layout Hardwired - example layout only Input Voltage Range 176-276V without derating (up to 100–276V with derating) Nominal Voltage 200/208/220/230/240V Frequency 50/60 Hz autoselection Frequency Range 40-70 Hz Short Circuit Current 90 A THDI <5% Electrical Output Voltages 200/208/220/230/240V +/– 1% Voltage THD < 2% Outlets (8) IEC-320-C13 C13 (2) IEC-320-C19 C19 Hardwired - see manual for terminal block layout Hardwired - example layout only Overload Capacity 102–110% : 120s, 110–125%: 60s, 125–150%: 10s, >150%: 500ms Efficiency (Normal Mode) Up to 94% in Online mode, 98% in Hi-Efficiency mode Output Frequency 50/60 Hz autoselect, frequency converter as standard Load Crest Factor 3:1 Battery Battery Management ABM® and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units. Extended Battery Capability EBM with Rack Kit Communications User Interface Multilingual graphical LCD display Communication Ports 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 mini terminal block for remote On/Off and 1 for remote power Off Communication Slot 1 slot for Network-MS card, ModBus-MS or Relay-MS cards. Environmental & Standards Audible Noise <45dB Operating Temperature 0 to 40°C continuous Safety markings IEC/EN 62040-1, UL 1778, CSA 22.2 EMC Markings IEC/EN 62040 -2 , FCC Class A, IEC/EN 62040-3 (Performance) Approvals CE, CB report (TUV), UL
General Topology On-line double conversion with PFC (Power Factor Correction) system Configuration Rack/Tower Part Number 9SX6KiRT Rating (VA/Watts) 6000/5400 Dimensions (H x W x D, mm) 440 x 130 x 685 Weight (kg) 48 Warranty 2 years warranty Rail Kit Included Yes Electrical Input Connection Hardwired - see manual for terminal block layout Hardwired - example layout only Input Voltage Range 176-276V without derating (up to 100–276V with derating) Nominal Voltage 200/208/220/230/240V Frequency 50/60 Hz autoselection Frequency Range 40-70 Hz Short Circuit Current 90 A THDI <5% Electrical Output Voltages 200/208/220/230/240V +/– 1% Voltage THD < 2% Outlets (8) IEC-320-C13 C13 (2) IEC-320-C19 C19 Hardwired - see manual for terminal block layout Hardwired - example layout only Overload Capacity 102–110% : 120s, 110–125%: 60s, 125–150%: 10s, >150%: 500ms Efficiency (Normal Mode) Up to 94% in Online mode, 98% in Hi-Efficiency mode Output Frequency 50/60 Hz autoselect, frequency converter as standard Load Crest Factor 3:1 Battery Battery Management ABM® and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units. Extended Battery Capability EBM with Rack Kit Communications User Interface Multilingual graphical LCD display Communication Ports 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 mini terminal block for remote On/Off and 1 for remote power Off Communication Slot 1 slot for Network-MS card, ModBus-MS or Relay-MS cards. Environmental & Standards Audible Noise <45dB Operating Temperature 0 to 40°C continuous Safety markings IEC/EN 62040-1, UL 1778, CSA 22.2 EMC Markings IEC/EN 62040 -2 , FCC Class A, IEC/EN 62040-3 (Performance) Approvals CE, CB report (TUV), UL